Previous Page  57 / 482 Next Page
Information
Show Menu
Previous Page 57 / 482 Next Page
Page Background

volumetric measurement & liquid handling

037

Takeoff thevariable

volumeknob.

Then insert the fixed

volumeknob.

Change your variable volume

pipette to a fix-volume pipette in

seconds.

Use one variable-volume pipette with

many pre-calibrated fix-volume knobs

and substantially reduce costs.

Take off the variable volume control

knob and insert any desired fix-volume

knob in seconds.

Save time by no longer turning

micrometer dials.

Eliminate setting errors by using pre-

calibrated knobs. Fix-volume knobs are

calibrated for consistent pipetting the

same amount.

Unlike to other autoclavable

pipettes, our pipettes require no

volume calibration after sterilization

process.

Durable PP/PVDF/anodised alumin-

ium and stainless steel body construc-

tion and stainless steel spring enable

easy and safe sterilization.

First take off the volume knob. Then

put the main body into the autoclave.

The pipette body can be fully auto-

clavable at 121°C and 0,1 MPa condi-

tions for 20 minutes.

Traditional pipettes

needs continuous

maintenance.

Small plastic seals and

“O” rings wear-out often and

need frequent replacement.

Plastic shaft wear down

from the friction involved

with tip loading and needs

frequent replacement.

Plastic body provides

a single seal and might

not protect fragile internal

components against impact.

Ultimate interior design

allows almost no

maintenance.

Steel alloy plunger does not

bend or brake. Thick polymer

sealsdonot split or leak.

Robust steel alloy body

protects internal components

and impact damage if

dropped. Largeejectionspring

provides lowejection forces.

Aluminium alloy shaft

does not wear down from

loading friction.

Guaranteed autoclave sterilization

without the risk of volume

recalibration.

Exchangeable volume control knobs

ordering info for volume knobs

catalogue

number

technical specification of volume knobs

011.23.001

011.23.002

011.24.005

011.24.010

011.25.010

011.25.020

011.26.020

011.26.025

011.26.050

011.27.030

011.27.050

011.27.100

011.28.100

011.28.200

011.29.300

011.30.500

011.30.901

011.31.925

1 µl fixed volume controller knob for 0.2 - 2 µl pipette

2 µl fixed volume controller knob for 0.2 - 2 µl pipette

5 µl fixed volume controller knob for 0.5 - 10 µl pipette

10 µl fixed volume controller knob for 0.5 - 10 µl pipette

10 µl fixed volume controller knob for 2 - 20 µl pipette

20 µl fixed volume controller knob for 2 - 20 µl pipette

20 µl fixed volume controller knob for 5 - 50 µl pipette

25 µl fixed volume controller knob for 5 - 50 µl pipette

50 µl fixed volume controller knob for 5 - 50 µl pipette

30 µl fixed volume controller knob for 10 - 100 µl pipette

50 µl fixed volume controller knob for 10 - 100 µl pipette

100 µl fixed volume controller knob for 10 - 100 µl pipette

100 µl fixed volume controller knob for 20 - 200 µl pipette

200 µl fixed volume controller knob for 20 - 200 µl pipette

300 µl fixed volume controller knob for 30 - 300 µl pipette

500 µl fixed volume controller knob for 100 - 1000 µl pipette

1000 µl fixed volume controller knob for 100 - 1000 µl pipette

2,5 ml fixed volume controller knob for 1 - 5 ml pipette

pack

quantity

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

ultimate interior design